LeCroy 2366 を用いた BLP (Beam Line Polarimeter) 回路 I/O pin assignment (*)On board SUN 仕様 Rear(DAQ and Bufch) Bit file name : Rblpe2.bit(rblpe2b.bit) 1:input A-01 Init. Signal A-02 OPR1 A-03 OPR2 A-04 external change siganl: Not used A-05 WSI-1 : from FERA A-06 WSI-2 :: Not used A-07 WAI-1 : from HSM(Signal OR input) A-08 WAI-2 :: Not used (From Front BLP:B-01->B-08) B-01 Trigger Accept B-02 Trigger Request(after Sampling) B-03 BLP1 Events B-04 BLP2 Events B-05 True Events B-06 Chance Events B-07 Spin up pulse B-08 Spin down pulse B-09 INV(RUN) from run_controller B-10 REQ from FERA B-11 external VETO B-12 extarnal Buffer Busy: Not used B-13 INV(BLP1 HATA IN) B-14 INV(BLP2 HATA IN) B-15 INV(Spin up) B-16 INV(Spin down) 2:output C-01 BUF1: Not used(diagonostic) C-02 BUF2: Not used(diagonostic) C-03 IPR1 C-04 IPR2 C-05 BUF1 Pulse: Not used? C-06 BUF2 Pulse: Not used? C-07 buffer change signal C-08 bufch Busy(diagonostic) C-09 WAO-1 C-10 WAO-2: Not used C-11 WSO-BUF1-1 C-12 WSO-BUF1-2: Not used C-13 WSO-BUF2-1 C-14 WSO-BUF2-2: Not used C-15 scaler Gate for Spin up C-16 scaler Gate for Spin down D-01 FCET Trigger D-02 Fast Clear D-03 Trigger veto(for Front BLP:A-04) D-04 FERA Busy (diagonostic) D-05 Spin up for IPR(InPut Register) ch.2 D-06 Spin down for IPR ch.3 D-07 event scaler bit 1 D-08 event scaler bit 2 D-09 event scaler bit 3 D-10 event scaler bit 4 D-11 event scaler bit 5 D-12 event scaler bit 6 D-13 BLP1 Events for IPR ch.13 D-14 BLP2 Events for IPR ch.14 D-15 True Events for IPR ch.15 D-16 Chance Events for IPR ch.16