差分
このページの2つのバージョン間の差分を表示します。
両方とも前のリビジョン前のリビジョン次のリビジョン | 前のリビジョン | ||
research:memos:gr:gr_memo [2017/12/08 09:22] – [Dispersion matching] kobayash | research:memos:gr:gr_memo [2022/05/21 21:28] (現在) – kobayash | ||
---|---|---|---|
行 2: | 行 2: | ||
==== Preparation ==== | ==== Preparation ==== | ||
+ | |||
+ | === A/C === | ||
+ | * Call OGFA sfatt (ext.: 8890) | ||
=== VDCs === | === VDCs === | ||
行 117: | 行 120: | ||
- Q1-magnet defocus with the sieve slit and the carbon target | - Q1-magnet defocus with the sieve slit and the carbon target | ||
==== Restrictions ==== | ==== Restrictions ==== | ||
- | * p 400 MeV - 10 nA at SC-FC | + | * p 400 MeV - 10 nA (better less few nA) at SC-FC |
* p 300 MeV - 20 nA at SC-FC | * p 300 MeV - 20 nA at SC-FC | ||
+ | * 3He 420 MeV - 10 pnA at D1-FC (maybe too high) | ||
+ | * | ||
==== E404 ==== | ==== E404 ==== | ||
* Beam transportation | * Beam transportation | ||
行 155: | 行 160: | ||
==== Resolutions ==== | ==== Resolutions ==== | ||
* Achromatic mode | * Achromatic mode | ||
- | * p 300 MeV : 60-100 keV | + | * p 295 MeV : 60-100 keV (FWHM) |
- | * 12C 1200 MeV : 240 - 400 keV | + | * p 392 MeV : 80 keV (FWHM), best resolution |
+ | * 12C 1200 MeV : 240 - 400 keV (FWHM) | ||
==== For 12C beam at 250 MeV (E404, Tsumura-san' | ==== For 12C beam at 250 MeV (E404, Tsumura-san' | ||
行 174: | 行 180: | ||
* Keep the GR and LAS chambers vacuum | * Keep the GR and LAS chambers vacuum | ||
* isobutane is used also by EN (but GR- and LAS-VDCs are the main users) | * isobutane is used also by EN (but GR- and LAS-VDCs are the main users) | ||
+ | * Right-hand system for GR and LAS | ||
+ | * Q1-FC angle coverage: 0 - ~20 deg. | ||
+ | |||